PRMA00BRA Site Information Form (site log) International GNSS Service See Instructions at: https://files.igs.org/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : IBGE Date Prepared : 2023-05-25 Report Type : UPDATED If Update: Previous Site Log : prma00bra_20210512.log Modified/Added Sections : 4.4,4.5 1. Site Identification of the GNSS Monument Site Name : Maringá Four Character ID : PRMA Monument Inscription : 96048 IERS DOMES Number : 41674M001 CDP Number : (A4) Monument Description : PILLAR Height of the Monument : (m) Monument Foundation : CONCRETE BLOCK, ROOF Foundation Depth : (m) Marker Description : Concrete pillar(3,60 m of height) built at top of two floor building, with force centering device on top. Date Installed : 2008-12-08T00:00Z Geologic Characteristic : (BEDROCK/CLAY/CONGLOMERATE/GRAVEL/SAND/etc) Bedrock Type : (IGNEOUS/METAMORPHIC/SEDIMENTARY) Bedrock Condition : (FRESH/JOINTED/WEATHERED) Fracture Spacing : (1-10 cm/11-50 cm/51-200 cm/over 200 cm) Fault zones nearby : (YES/NO/Name of the zone) Distance/activity : (multiple lines) Additional Information : The reference point of station is the top force centering device. The station is installed on the Campus of Universidade Estadual de Maringá (UEM) Bloco 102, na Avenida Colombo, Maringá, Paraná state. 2. Site Location Information City or Town : Maringa State or Province : Parana Country : Brazil Tectonic Plate : Approximate Position (SIRGAS2000) X coordinate (m) : 3610720.8 Y coordinate (m) : -4611288.3 Z coordinate (m) : -2518636.3 Latitude (N is +) : -232434.87 Longitude (E is +) : -0515618.32 Elevation (m,ellips.) : 543.3 Additional Information : (multiple lines) 3. GNSS Receiver Information 3.1 Receiver Type : TRIMBLE NETRS Satellite System : GPS+GLO Serial Number : 4643124421 Firmware Version : 1.2-0 Elevation Cutoff Setting : 0 Date Installed : 2008-12-08T00:00Z Date Removed : 2014-04-14T11:30Z Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 3.2 Receiver Type : TRIMBLE NETR8 Satellite System : GPS+GLO Serial Number : 4906K34417 Firmware Version : 4.70 Elevation Cutoff Setting : 0 Date Installed : 2014-04-14T16:45Z Date Removed : 2015-02-06T12:09Z Temperature Stabiliz. : Additional Information : 3.3 Receiver Type : TRIMBLE NETR8 Satellite System : GPS+GLO Serial Number : 4906K34417 Firmware Version : 4.87 Elevation Cutoff Setting : 0 Date Installed : 2015-02-06T12:10Z Date Removed : 2017-11-17T12:19Z Temperature Stabiliz. : Additional Information : 3.4 Receiver Type : TRIMBLE NETR8 Satellite System : GPS+GLO Serial Number : 4906K34417 Firmware Version : 48.01 Elevation Cutoff Setting : 0 Date Installed : 2017-11-17T12:20Z Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : Additional Information : 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+CMP+QZSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : TRM41249.00 NONE Serial Number : 60179279 Antenna Reference Point : BAM Marker->ARP Up Ecc. (m) : 0.0080 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : 2008-12-08T00:00Z Date Removed : 2014-04-14T11:30Z Additional Information : (multiple lines) 4.2 Antenna Type : TRM59800.00 NONE Serial Number : 4938353434 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0080 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : Antenna Cable Length : 30 Date Installed : 2014-04-14T16:45Z Date Removed : 2014-06-11T15:00Z Additional Information : 4.3 Antenna Type : TRM29659.00 NONE Serial Number : 0220071006 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0080 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : Antenna Cable Length : 30 Date Installed : 2014-06-11T15:30Z Date Removed : 2015-03-25T17:00Z Additional Information : 4.4 Antenna Type : TRM59800.00 NONE Serial Number : 4938353434 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0080 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : Antenna Cable Length : 30 Date Installed : 2015-03-25T17:42Z Date Removed : 2023-05-24T14:00Z Additional Information : 4.5 Antenna Type : TRM59800.00 NONE Serial Number : 4940353510 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0080 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : Antenna Cable Length : 30 Date Installed : 2023-05-24T19:30Z Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.1 Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : PTU303 Manufacturer : Vaisala Serial Number : Data Sampling Interval : 60 Accuracy (% rel h) : 1 Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : 2014-04-14 Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : PTU303 Manufacturer : Vaisala Serial Number : Data Sampling Interval : 60 Accuracy : 0.3 Height Diff to Ant : (m) Calibration date : 2014-04-14 Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : PTU303 Manufacturer : Vaisala Serial Number : Data Sampling Interval : 60 Accuracy : 0.2 Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : 2014-04-14 Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.1 Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.1 Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.1 Signal Obstructions : (TREES/BUILDLINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDLINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.1 Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Instituto Brasileiro de Geografia e Estatistica : Brazilian Institute of Geography and Statistics) Preferred Abbreviation : IBGE Mailing Address : Avenida Republica do Chile, 500 - CEP 20031-170 : Rio de Janeiro - RJ - Brazil Primary Contact Contact Name : IBGE Telephone (primary) : Telephone (secondary) : Fax : E-mail : rbmc@ibge.gov.br Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : 12. Responsible Agency (if different from 11.) Agency : (multiple lines) Preferred Abbreviation : (A10) Mailing Address : (multiple lines) Primary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : (multiple lines) 13. More Information Primary Data Center : https://geoftp.ibge.gov.br/informacoes_sobre_ posicionamento_geodesico/rbmc/ Secondary Data Center : URL for More Information : Hardcopy on File Site Map : (Y or URL) Site Diagram : (Y or URL) Horizon Mask : (Y or URL) Monument Description : (Y or URL) Site Pictures : (Y or URL) Additional Information : (multiple lines) Antenna Graphics with Dimensions (insert text graphic from file antenna.gra) <-- 0.381 --> TRM41249.00 / ----------------------+--------------------- \ <-- 0.0714 L1 + + + <-- 0.0682 L2 \ -------------------------------------------- / \ / \ / \-----+-----/ <-- 0.0000 ARP=BAM <-- 0.3396 --> ARP: Antenna Reference Point L1 : L1 Phase Center L2 : L2 Phase Center TCR: Top of Chokering BCR: Bottom of Chokering TRM159800.00 TRM159900.00 TRM29659.00 TRM59800.00 TRM59800.00C TRM59800.80 TRM59800.99 TRM59900.00 ----- / \ | | +-------------------------------------------------+ <-- 0.1020 TCR | | | | | | | | +-+-------------------------------------------------+-+ <-- 0.0381 +-------------------+-------------+-------------------+ <-- 0.0350 BCR | | =| | +------x------+ <-- 0.0000 BPA=ARP RXC=NRP <-- 0.3810 -->